Product
产品中心

QK-S07

Therapeutic mechanism

The general chair therapy device (specifically designed for the head and five senses, digestive system, gynecology, and male diseases) is designed based on the therapeutic effects and clinical experience of multi peak broadband strong life energy nano waves on diseases such as the head and five senses, digestive system, gynecology, and male diseases. The multi peak broadband energy waves emitted by the general practitioner therapy device match the absorption range covering the human body and are easily absorbed and activated by human tissue cells, thereby rapidly producing thermal and other biological effects in the body. It can improve blood circulation, reduce peripheral nerve excitability, regulate endocrine and hormone secretion, enhance sexual function, promote tissue cell repair and regeneration, and absorb exudate, playing a role in promoting blood circulation, removing blood stasis, anti-inflammatory and analgesic effects.

scope of application

Trauma, wound healing after surgery, chronic gastritis, chronic cholecystitis, pharyngitis, vasculitis, cervical spondylosis, rheumatism, knee arthritis, hyperthyroidism, hypothyroidism, diabetes, chronic prostatitis, and chronic prostatic hypertrophy.

It has an improvement effect on local adverse reactions caused by radiotherapy in cancer patients, as well as on digestive side effects such as nausea and abdominal discomfort caused by chemotherapy. It also has a pain relieving effect on various pains caused by cancer.

Treatment guidance

Must be exposed for irradiation: The energy nano waves emitted by the therapeutic device can be absorbed or blocked by a layer of gauze, and the irradiated area must be exposed during irradiation.

Illumination distance: should be based on comfortable temperature. The distance between strong gears is about 20 centimeters, and the distance between weak gears is about 10 centimeters.

Radiation intensity (temperature): The radiation intensity should be selected according to the patient's condition and disease type. The irradiation temperature on the surface of adult skin is generally around 40 ℃, while that on infants and young children is around 30 ℃.

Exposure time: Depending on the condition, usually around 30 minutes per exposure site, 1-2 times a day. Emergency or critically ill patients should have their exposure time and frequency extended.

Main technical performance indicators

Main distribution range of energy waves: 6K-12Knm (nanometer)

Peak wavelength range of energy wave: 9300nm ±~465nm (nanometer)

Full normal emissivity: ≥ 83%

Total power: 1500VA

Power supply voltage: AC220V frequency 50/60Hz

AC110V frequency 50/60Hz

*This therapeutic device operates on 220V and 110V

Cannot be used universally, please purchase the model according to the local voltage used